Ysav90b Medical Digital Display Mobile Hospital Ventilator
2018-08-17 05:02:39
Model NO.: YSAV90B
Ptr: -10 ~ 10 Hpa
Display Mode: 10.4′′ LCD Display
Warranty Period: 12 Months
out Looking: Mobile
Ventilation Volume Alarm: ≥ 18L/ Min
I/E Ratio: 4:1~1:4, Has The Inverse Ratio Ventilation
Trademark: YSENMED
Transport Package: Wooden Case
Specification: CE certificate
Origin: China
medical digital display mobile hospital ventilatorYSAV90B
Details:
TECHNIQUES SPECIFICATIONS | |
Physical specifications | |
Display | 10.4'' LCD Display |
Mode: | pneumatically powered and electrically controlled system |
Trolley: | Fitted with 4Â nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications: | |
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve | <12.5 kPa |
Respiratory Rate | 1 ~Â 99 bpm |
gas concentration output | 21% ~Â 100% adjustable |
Maximum Minute ventilation | ≥18L / min |
modes of ventilation | A/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL |
Ventilator compliance | ≤30 Ml/kPa |
PEEP: | 0 ~Â 1.0 kPa |
Ptr: | -10 ~Â 10 hPa |
IMV frequency: | 1~20 bpm |
I/E Ratio: | 4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume | Setting Range: 50~1500MLÂ Â Â Â Â Display Range: 0~2000ml ;Â Â Â resolution ratio: 10ml |
Inspiratory Plateau: | 0~1s |
Maximum Safety Pressure | ≤ 6.0kPa |
Sigh: | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range: | 1.0~ 6.0kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.1 kPa ~Â 6.0 kPa;Â Â Â Upper: 0Â ~ 5.0 kPa |
 | ±0.2 kPa |
Ventilation Volume alarm: | ≥ 18L/ MIN |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. | |
Operating conditions | |
Ambient temperature: | 10 ~Â 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~Â 1060 hPa |
Power requirement: | 100-120 Vac, 50/60 Hz;Â |
Attention: the AC power supply used for the anesthesia machine must be well     grounded. | |
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
Storage | |
Ambient temperature: | -15oC ~Â +50oC |
Relative humidity: | no higher than 95 % |
Atmospheric pressure: | 86 kPa ~Â 106 kPa. |
 | It should be stored in a room without corrosive gas and well ventilated |
Package | |
packaging box | comply with the requirement of GB/T 15464 |
 | Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation |
 | Moisture protection and rain protection to ensure that product is protected from natural damage. |
Safty &Â Alarm | |
Gas source pressure | Immediate alarm; "high level alarm" indicator flickers raising an audible alarm. |
Airway Pressure Alarm | The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm. |
Tidal Volume Alarm | Lower than 50ml, The alarm will be raised after one breathing cycle. |
Ventilation Volume Alarm | Lower: 0~12L/Min;Â Â Â Up: 18L/ Min |
Battery Voltage Alarm | It alrms when the battery voltage is lower than 10.5V. |
Power On Self Test | Self test before working, assure it's working normally. |
STANDARD CONFIGURATIONS | |
QTY | NAME |
1 set | Main unit |
4 pcs | Adult threaded pipe (Silica) |
1 set | Child threaded pipe (single use) |
1 pc | Oxygen Tube |
1pc | Y-Pipe |
2pcs | Mask (Silicom) |
2pcs | Leather Bag |
2pcs | Fuse |
1pc | Power Line |
1pc | Oxygen pressure reducer |
4 pcs | Hoop |
1pc | Battery |
1pc | Tools Attachment |
1 set | humidifier |
1 set | English Version User Manual |
We are a company aiming to make one stop shopping for our customers. We equiped
hospital operation room with many kind of items like operation table, orthopedic drill and
saw, ECG,defibrillator etc.
We listed some hospital operation room items basic items for your reference as below:
operation room | anesthesia machine |
ventilator | |
operating lamp | |
operation table | |
Pendant | |
medical drill and saw | |
ECG | |
patient monitor | |
Defibrillator | |
infusion pump | |
Electrocoagulation | |
oxygen generator | |
electric suction device | |
autoclave sterilizer |
Â
Â
Mini Tuo Cha Pu 'Er Tea: Pu-erh tea is post-fermented. This means Pu-erh tea's processing includes both fermentation and then prolonged storage, or "aging," under high humidity. Pu-erh tea that is aged for a longer period of time is supposed to taste better.It has a mellow, pure, rich flavor.Super high quality, whole leaves mini pu erh tea. Full of high, deep ripe Pu Er aroma, with soft & smooth tea liquid, sweet taste, complex tea texture on the mouth after sipping the liquid.